Customization: | Available |
---|---|
Theory: | Electromagnetic Relay |
Usage: | Car Relay, Household Appliances Relay, Communication Relay |
Still deciding? Get samples of US$ 0.1/Piece
Request Sample
|
Suppliers with verified business licenses
Relay is an automatic switching element with an isolation function. It is widely used in remote control, telemetry, communication, automatic control, mechatronics, and power electronic equipment. It is one of the most important control elements.
Selection Manual Of DECHUANG Industrial Control Relay(Contact us for more details)
The relay generally has an induction mechanism (input part) that can reflect certain input variables (such as current, voltage, power, impedance, frequency, temperature, pressure, speed, light, etc.); Between the input part and the output part of the relay, there is an intermediate mechanism (drive part) that couples and isolates the input quantity, processes the function and drives the output part.
As a control element, to sum up, the relay has the following functions:
1) Expand the control range: For example, when the control signal of a multi-contact relay reaches a certain value, it can switch, break, and connect multiple circuits at the same time according to different forms of contact groups.
2) Amplification: For example, sensitive relays, intermediate relays, etc., with a very small amount of control, can control circuits with high power.
3) Integrated signal: For example, when multiple control signals are input to the multi-winding relay in a specified form, the predetermined control effect is achieved after comparison and synthesis.
4) Automatic, remote control, monitoring: For example, the relay on the automatic device can form a program control circuit together with other electrical appliances to realize automatic operation.
REH Power Relay
2 pole 3 pole contact load 16A
With non-polarity LED integrated into relay
With lockable test button and inspection window
Identification of coils through test button color (AC red/DC blue)
Conformity with RoHS Directive
Characteristics | ||||||||||||||||||||||
Configuration | 1A,1B | 2A,2B,2FO | 3A | |||||||||||||||||||
Contact | Load | Resistance | 16A/500VAC | 16A/250VAC | 16A/300VAC | |||||||||||||||||
Resistance | 10A/220VDC 16A/30VDC | |||||||||||||||||||||
inductive | 10A/250VAC(cosØ0.4); 3A/220VDC(L/R=7ms) |
|||||||||||||||||||||
Switching capacity | Resistance | 8000VA | 4000VA | 4800VA | ||||||||||||||||||
Resistance | 2200W | |||||||||||||||||||||
inductive | 2500VA(cosΦ0.4);660W(L/R=7ms) | |||||||||||||||||||||
Initial contact resistance | ≤50mΩ | |||||||||||||||||||||
Material | Ag alloy | |||||||||||||||||||||
Electric durability(110%rated voltage, 55ºC) | ≥60 x 104Cycles (600 Ops/h) | ≥20 x 104Cycles (600 Ops/h) | ||||||||||||||||||||
Mechanical durability | ≥5000 x 104Cycles (18000 Ops/h) | |||||||||||||||||||||
Pick-up voltage (23ºC) (Rated voltage) | DC:≤75% , AC:≤80% 50/60Hz | |||||||||||||||||||||
Drop-out voltage (23ºC) (Rated voltage) | DC:≥10% , AC:≥30% 50/60Hz | |||||||||||||||||||||
Maximum voltage (23ºC) (Rated voltage) | 110% | |||||||||||||||||||||
Insulation resistance | ≥1000MΩ (500VDC) | |||||||||||||||||||||
Coil operating power | DC (W) | approx. 1.5 | ||||||||||||||||||||
AC (VA) | approx. 2.5 | |||||||||||||||||||||
Operate time&Release time (at nominal voltage) | ≤20ms | |||||||||||||||||||||
Initial breakdown voltage | Between open contacts | 1500VAC/1min (leakage current 1mA) | ||||||||||||||||||||
Between poles | 4000VAC/1min (leakage current 1mA) | |||||||||||||||||||||
Between contacts and coil | 4000VAC/1min (leakage current 1mA) | |||||||||||||||||||||
Insulation characteristics IEC 60664 UL840 |
Rated voltage | 400VAC | 250VAC | 250VAC | ||||||||||||||||||
Pollution level | 2 | 3 | 3 | |||||||||||||||||||
Overvoltage level | II | III | III | |||||||||||||||||||
Protection level | IP50 | |||||||||||||||||||||
Storage temperature/ humidity | -20~+85ºC/ ≤85%RH (18 months) | |||||||||||||||||||||
Working temperature/ humidity | -40~+55ºC/ 5%~85%RH (No condensation) | |||||||||||||||||||||
Air pressure | 86~106KPa | |||||||||||||||||||||
Shock resistance | 10G (half-sine shock pulse: 11ms) | |||||||||||||||||||||
Vibration resistance | 10~55Hz double-amplitude:1.0mm | |||||||||||||||||||||
Mounting | plugin | |||||||||||||||||||||
Unit weight | approx. 90g |